• DocumentCode
    1089892
  • Title

    The effect of phase cancellation on estimates of broadband ultrasound attenuation and backscatter coefficient in human calcaneus in vitro

  • Author

    Wear, Keith A.

  • Author_Institution
    U.S. Food & Drug Adm., Silver Spring
  • Volume
    55
  • Issue
    2
  • fYear
    2008
  • fDate
    2/1/2008 12:00:00 AM
  • Firstpage
    384
  • Lastpage
    390
  • Abstract
    Broadband ultrasound attenuation (BUA) is a clinically proven indicator of osteoporotic fracture risk. BUA measurements are typically performed in through- transmission with single-element phase sensitive (PS) receivers and therefore can be compromised by phase cancellation artifact. Phase-insensitive (PI) receivers suppress phase cancellation artifact. To study the effect of phase cancellation on BUA measurements, through-transmission measurements were performed on 16 human calcaneus samples in vitro using a two-dimensional receiver array that enabled PS and PI BUA estimation. The means plus or minus standard deviations for BUA measurements were 22.1 plusmn 15.8 dB/MHz (PS) and 17.6 plusmn 7.2 dB/MHz (PI), suggesting that, on the average, approximately 20% of PS BUA values in vitro can be attributed to phase cancellation artifact. Therefore, although cortical plates are often regarded as the primary source of phase cancellation artifact, the heterogeneity of cancellous bone in the calcaneal interior may also be a significant source. Backscatter coefficient estimates in human calcaneus that are based on PS attenuation compensation overestimate 1) average magnitude of backscatter coefficient at 500 kHz by a factor of about 1.6 plusmn 0.3 and 2) average exponent (n) of frequency dependence by about 0.34 plusmn 0.12 (where backscatter coefficient is fit to a power law form proportional to frequency to the nth power).
  • Keywords
    biomechanics; biomedical ultrasonics; bone; fracture; medical signal processing; backscatter coefficient; broadband ultrasound attenuation; human calcaneus; osteoporotic fracture risk; phase cancellation; phase sensitive receivers; phase-insensitive receivers; Algorithms; Calcaneus; Computer Simulation; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Models, Biological; Scattering, Radiation;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2008.656
  • Filename
    4460872