• DocumentCode
    1097818
  • Title

    Accuracy of AC Transport Current Loss in HTS Tape Measurements Using a Pick-Up Loop

  • Author

    Ogawa, Jun ; Fukui, Satoshi ; Oka, Tetsuo ; Sato, Takao ; Maruko, Atsushi ; Tanaka, Hiroshi

  • Author_Institution
    Grad. Sch. of Sci. & Technol., Niigata Univ., Niigata, Japan
  • Volume
    19
  • Issue
    3
  • fYear
    2009
  • fDate
    6/1/2009 12:00:00 AM
  • Firstpage
    2391
  • Lastpage
    2394
  • Abstract
    AC transport current loss in high temperature superconducting (HTS) tapes can be measured without a direct electrical connection by using a pick-up loop method. This method requires a correction factor, which is related to the ratio of the linkage magnetic flux determined by the distribution of the transport current in the HTS tape and pick-up loop. In this study, to determine the accuracy of the AC transport current loss measurement using a pick-up loop method, we measured the critical current and AC transport current loss distribution in the tape axis. We found the pick-up loop voltage of the deteriorated section of the HTS tape to be higher than in the normal section with the same transport current. We concluded that the pick-up loop method accuracy is sufficient to measure the AC transport current loss in HTS tapes.
  • Keywords
    current distribution; electric current measurement; high-temperature superconductors; loss measurement; magnetic flux; superconducting tapes; AC transport current loss measurement; HTS tape measurement; correction factor; direct electrical connection; high temperature superconducting tape; linkage magnetic flux; pick-up loop; transport current distribution; AC transport current loss measurement; correction factor; pick-up loop method;
  • fLanguage
    English
  • Journal_Title
    Applied Superconductivity, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1051-8223
  • Type

    jour

  • DOI
    10.1109/TASC.2009.2019546
  • Filename