DocumentCode
1103521
Title
Body-effect nonlinearity in infrared focal plane array multiplexers
Author
Perry, David L. ; Hubbs, John E. ; Dereniak, Eustace L.
Author_Institution
Opt. Sci. Center, Arizona Univ., Tucson, AZ, USA
Volume
41
Issue
6
fYear
1994
fDate
6/1/1994 12:00:00 AM
Firstpage
1062
Lastpage
1063
Abstract
A hypothetical source-follower-per-detector multiplexer circuit is introduced. An analysis of its DC transfer function is presented, accounting for nonlinearity produced by the body-to-substrate bias. Calculated and measured transfer functions for an actual multiplexer are discussed. Effects of nonlinearity on nonuniformity-corrected infrared imaging are illustrated
Keywords
image sensors; infrared imaging; multiplexing equipment; nonlinear network analysis; signal processing equipment; transfer functions; DC transfer function; IR imaging; body-effect nonlinearity; body-to-substrate bias; infrared focal plane array; source-follower-per-detector multiplexer circuit; Capacitance; Circuit testing; Infrared detectors; Infrared imaging; Intrusion detection; MOSFETs; Multiplexing; Sensor arrays; Silicon; Transfer functions;