DocumentCode
1103598
Title
Design study of a 60 T pulsed magnet with 10 μs risetime
Author
Li, L. ; van Bockstal, L. ; Herlach, F. ; Van Amersfoort, W.
Author_Institution
Lab. voor Vaste Stof-Fysika en Magnetisme, Katholieke Univ., Leuven, Belgium
Volume
32
Issue
4
fYear
1996
fDate
7/1/1996 12:00:00 AM
Firstpage
2511
Lastpage
2513
Abstract
A 60 T nondestructive pulsed magnet for the “Free Electron Laser for Infrared Experiments” (FELIX) is developed. As a rise time of 10 μs is required, the magnet is designed consisting of two coils in order to cope with the skin effect and power requirements. Each of the coils is energized by its own capacitor bank. The inner coil is composed of 2 helices made from copper tubes; it is energized by a 12 kV, 0.1 mF capacitor bank to generate 30 T with 20 μs pulse duration. The 60 T field is obtained by adding a 30 T field from the outer coil with 5 ms pulse duration energized by a 5 kV, 8 mF capacitor bank. The basic design criteria, the coil modeling and manufacturing techniques are discussed
Keywords
electromagnets; skin effect; 10 mus; 60 T; Cu; FELIX; capacitor bank; copper tubes; design; helical coils; nondestructive pulsed magnet; risetime; skin effect; Coils; Copper; Current density; Equations; Glass; Inductance; Magnetic analysis; Optical fiber cables; Skin effect; Wire;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.511383
Filename
511383
Link To Document