• DocumentCode
    1103598
  • Title

    Design study of a 60 T pulsed magnet with 10 μs risetime

  • Author

    Li, L. ; van Bockstal, L. ; Herlach, F. ; Van Amersfoort, W.

  • Author_Institution
    Lab. voor Vaste Stof-Fysika en Magnetisme, Katholieke Univ., Leuven, Belgium
  • Volume
    32
  • Issue
    4
  • fYear
    1996
  • fDate
    7/1/1996 12:00:00 AM
  • Firstpage
    2511
  • Lastpage
    2513
  • Abstract
    A 60 T nondestructive pulsed magnet for the “Free Electron Laser for Infrared Experiments” (FELIX) is developed. As a rise time of 10 μs is required, the magnet is designed consisting of two coils in order to cope with the skin effect and power requirements. Each of the coils is energized by its own capacitor bank. The inner coil is composed of 2 helices made from copper tubes; it is energized by a 12 kV, 0.1 mF capacitor bank to generate 30 T with 20 μs pulse duration. The 60 T field is obtained by adding a 30 T field from the outer coil with 5 ms pulse duration energized by a 5 kV, 8 mF capacitor bank. The basic design criteria, the coil modeling and manufacturing techniques are discussed
  • Keywords
    electromagnets; skin effect; 10 mus; 60 T; Cu; FELIX; capacitor bank; copper tubes; design; helical coils; nondestructive pulsed magnet; risetime; skin effect; Coils; Copper; Current density; Equations; Glass; Inductance; Magnetic analysis; Optical fiber cables; Skin effect; Wire;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/20.511383
  • Filename
    511383