  • Abstract
    The problem considered here concerns simulating the electromagnetic environment for electromagnetic susceptibility (EMS) measurements over a wide frequency range. Means of bridging the existing gap between low-and high-frequency techniques are suggested by extending the use of anechoic-type chambers downward in frequency. Results of measurements over a wide frequency range are presented to demonstrate the behavior of such absorber-lined chambers (ALC´s). Basic criteria and guidelines for the design of ALC´s are proposed.
  • Keywords
    Anechoic chambers; Antenna measurements; Automatic logic units; Circuits; Costs; Electromagnetic devices; Electromagnetic measurements; Frequency measurement; Guidelines; Medical services; Anechoic chambers; broad band; design criteria; guidelines;