DocumentCode
1113532
Title
A test facility for 200 kA SMES/ETM conductors
Author
Zeigler, J. ; Colvin, J. ; Huson, R. ; Rocha, R. ; Shotzman, G. ; Michels, P. ; Peck, S.
Author_Institution
Texas Accel. Center, Woodlands, TX, USA
Volume
27
Issue
2
fYear
1991
fDate
3/1/1991 12:00:00 AM
Firstpage
2395
Lastpage
2398
Abstract
The test facility and the procedures used to characterize two full-scale copper-stabilized cable-in-conduit superconductors are described. The critical current at 1.8 K was 280 kA at a total field of 5.8 T, 260 kA at 6.4 T, and 215 kA at 7.4 T. The stability margin at 200 kA and 4 to 5 T was 70 to 80 mJ/cm3 of metal. No significant performance degradation was observed after more than 600 load cycles
Keywords
cable testing; critical currents; superconducting cables; test facilities; 1.8 K; 200 to 280 kA; 4 to 7.4 T; SMES/ETM conductors; cable-in-conduit superconductors; critical current; stability margin; superconducting magnetic energy storage; test facility; Conductors; Helium; Life estimation; Magnetic field measurement; Power transformer insulation; Reservoirs; Samarium; Superconducting magnets; Test facilities; Testing;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/20.133701
Filename
133701
Link To Document