• DocumentCode
    1120675
  • Title

    Low-voltage ride-through of a full converter wind turbine with permanent magnet generator

  • Author

    Conroy, J.F. ; Watson, R.

  • Author_Institution
    Univ. Coll. Dublin, Dublin
  • Volume
    1
  • Issue
    3
  • fYear
    2007
  • fDate
    9/1/2007 12:00:00 AM
  • Firstpage
    182
  • Lastpage
    189
  • Abstract
    The low-voltage ride-through capability of a 2 MW full converter wind turbine with permanent magnet synchronous generator is investigated herein. A detailed description of the system, its controller options and its behaviour when subjected to a severe voltage dip, is presented. A control scheme for the turbine that allows it to withstand severe voltage dips is designed and simulated. This control scheme emphasises the regulation of the dc-link voltage and minimisation of the drive train torque surplus. Also, the level of modelling detail required for stability analysis is analysed and discussed.
  • Keywords
    permanent magnet generators; power system control; power system stability; synchronous generators; wind turbines; dc-link voltage; drive train torque surplus; full converter wind turbine; permanent magnet synchronous generator; power 2 MW; stability analysis;
  • fLanguage
    English
  • Journal_Title
    Renewable Power Generation, IET
  • Publisher
    iet
  • ISSN
    1752-1416
  • Type

    jour

  • DOI
    10.1049/iet-rpg:20070033
  • Filename
    4302792