• DocumentCode
    1126118
  • Title

    Test Suite for the LHCb Muon Chambers Quality Control

  • Author

    Bocci, V. ; Carboni, G. ; Massafferri, A. ; Nobrega, R. ; Santovetti, E. ; Sarti, A.

  • Author_Institution
    Univ. La Sapienza, Rome
  • Volume
    55
  • Issue
    2
  • fYear
    2008
  • fDate
    4/1/2008 12:00:00 AM
  • Firstpage
    723
  • Lastpage
    728
  • Abstract
    This paper describes the apparatus and the procedures implemented to test the front-end (FE) electronics of the LHCb muon detector multi wire proportional chambers (MWPC). Aim of the test procedure is to diagnose every FE channel of a given chamber by performing an analysis of the noise rate versus threshold and of the performances at the operational thresholds. Measurements of the key noise parameters, obtained while performing quality tests on the MWPC chambers before the installation on the experiment, are presented. The test suite proved to be an automatic, fast and user-friendly system for mass production tests of chambers. It provided the electronic identification of every chamber and FE board, and the storage and bookkeeping of test results that will be made available to the experiment control system during data taking.
  • Keywords
    multiwire proportional chambers; muon detection; noise; nuclear electronics; quality control; LHCb muon detector multiwire proportional chambers; MWPC; automatic system; electronic identification; front-end electronics; noise rate; operational thresholds; quality control system; user-friendly system; Automatic testing; Detectors; Electronic equipment testing; Iron; Mesons; Performance analysis; Performance evaluation; Quality control; System testing; Wire; Electronics; gas detectors; software quality; wire chambers;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2008.918522
  • Filename
    4484240