• DocumentCode
    113087
  • Title

    Implementation of a High-Precision 2-D Receiving Coil Set for Magnetic Particle Imaging

  • Author

    Weber, Matthias ; Bente, Klaas ; Graeser, Matthias ; Sattel, Timo F. ; Buzug, Thorsten M.

  • Author_Institution
    Grad. Sch. for Comput. in Med. & Life Sci., Univ. zu Lubeck, Lubeck, Germany
  • Volume
    51
  • Issue
    2
  • fYear
    2015
  • fDate
    Feb. 2015
  • Firstpage
    1
  • Lastpage
    4
  • Abstract
    In the medical imaging technique magnetic particle imaging, tomographic images of the spatial distribution of superparamagnetic particles are produced in real time. To generate images in a plane, the particles are excited in two dimensions. A specific particle response can be measured via receiving coils and the measured signal gives quantitative information about the particle distribution and local concentration. To achieve a high-spatial resolution with x-space reconstruction, the receiving coils have to feature a preferably homogeneous sensitivity in the field of view. To achieve this for a cylindrical bore, which is the typical medical scenario, an optimized coil set is implemented and tested in this paper. Two orthogonal receiving coil pairs are wound inside a negative form, which is custom made by a 3-D printer. Further, a well performing receiving chain is utilized, which transmits the particle signal from the receiving coils to the data acquisition unit. For performance evaluation, a hardware phantom with three delta samples is used. A field free line is chosen as a selection field, for which the presented coils may be used in an application scenario. The receiving coils perform well in the sense that no coupling in between the data paths is apparent and the recorded signals clearly represent the used phantom.
  • Keywords
    biomagnetism; biomedical imaging; coils; data acquisition; magnetic particles; phantoms; superparamagnetism; 2D receiving coil set; 3D printer; data acquisition; local concentration; magnetic particle imaging; medical imaging technique; mgnetic particle imaging; orthogonal receiving coil pairs; particle distribution; phantom; receiving coils; sensitivity; spatial distribution; superparamagnetic particles; tomographic images; x-space reconstruction; Atmospheric measurements; Coils; Magnetic particles; Particle measurements; Phantoms; Wires; Field free line (FFL); litz wire; magnetic particle imaging (MPI); receiving channel; receiving coil;
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2014.2331987
  • Filename
    7067497