DocumentCode
1131497
Title
Induction Motor Bearing Failure Detection and Diagnosis: Park and Concordia Transform Approaches Comparative Study
Author
Onel, I.Y. ; El Hachemi Benbouzid, Mohamed
Author_Institution
Yildiz Tech. Univ. (YTU), Istanbul
Volume
13
Issue
2
fYear
2008
fDate
4/1/2008 12:00:00 AM
Firstpage
257
Lastpage
262
Abstract
This paper deals with the problem of bearing failure detection and diagnosis in induction motors. Indeed, bearing deterioration is now the main cause of induction motor rotor failures. In this context, two fault detection and diagnosis techniques, namely the Park transform approach and the Concordia transform, are briefly presented and compared. Experimental tests, on a 0.75 kW two-pole induction motor with artificial bearing damage, outline the main features of the aforementioned approaches for small- and medium-size induction motors bearing failure detection and/or diagnosis.
Keywords
fault diagnosis; induction motors; machine bearings; rotors; Concordia transform; Park transform; artificial bearing damage; failure detection; failure diagnosis; induction motor bearing; induction motor rotor; power 0.75 kW; two-pole induction motor; Acceleration; Contamination; Corrosion; Fault detection; Fault diagnosis; Induction motors; Lubrication; Rotors; Vibration measurement; Water pollution; Bearing failure; Concordia transform; Park transform; diagnosis; fault detection; induction motor;
fLanguage
English
Journal_Title
Mechatronics, IEEE/ASME Transactions on
Publisher
ieee
ISSN
1083-4435
Type
jour
DOI
10.1109/TMECH.2008.918535
Filename
4489987
Link To Document