DocumentCode
1133492
Title
MTI Loss with Coherent Integration of Weighted Pulses
Author
Müller, Bernd
Author_Institution
Siemens AG Laboratories
Issue
4
fYear
1981
fDate
7/1/1981 12:00:00 AM
Firstpage
549
Lastpage
552
Abstract
A moving target indicator (MTI) preceding a coherent integrator causes a degradation in the signal-to-noise ratio (SNR). This negative effect can be reduced by weighting of the MTI output pulses before the integration process. Two examples are given which show the improvement in SNR and detection probability as a result of this weighting.
Keywords
Computational modeling; Degradation; Delay lines; Filter bank; Frequency; Laboratories; Noise reduction; Signal processing; Signal to noise ratio; Transfer functions;
fLanguage
English