DocumentCode
1138650
Title
Power supply system for the ATLAS muon spectrometer: design specifications and test
Author
Beretta, Matteo M. ; Lanza, Agostino ; Vandelli, Wainer ; Mikenberg, George ; Richter, Robert
Author_Institution
INFN, Rome, Italy
Volume
51
Issue
5
fYear
2004
Firstpage
2220
Lastpage
2226
Abstract
In this paper, the problem of the low-voltage (LV) and high-voltage (HV) power supply distribution of the monitored drift tubes (MDT) detector is addressed. Due to the high number of channels (1168 for low voltage and twice for high voltage) involved and to the dimension of the apparatus, these power supply systems are very complicated. Both systems are made of three different parts: a power generator, a system controller, and an active distributor. The first two parts will be localized in the cavern close to the experimental area, so they are subjected to standard environmental conditions. The third part (the active distributor) will be placed in the experimental area on the platforms just outside the detector, where the environmental conditions are more severe, due to the presence of magnetic field (about 0.08 T) and radiations. In the paper, we present the design specifications and tests for the power supply systems.
Keywords
magnetic fields; position sensitive particle detectors; power supplies to apparatus; readout electronics; 0.08 T; ATLAS muon spectrometer; active distributor; high-voltage power supply distribution; low-voltage power supply distribution; magnetic field; monitored drift tubes detector; power generator; power supply system; standard environmental conditions; system controller; Control systems; Detectors; Low voltage; Mesons; Monitoring; Power generation; Power supplies; Spectroscopy; System testing; Umbilical cable; ATLAS; muon spectrometer; power supply;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.2004.836038
Filename
1344313
Link To Document