DocumentCode
1145263
Title
Performance Evaluation of an Adaptive-Network-Based Fuzzy Inference System Approach for Location of Faults on Transmission Lines Using Monte Carlo Simulation
Author
Reddy, M. Jaya Bharata ; Mohanta, Dusmanta Kumar
Author_Institution
Dept. of Electr. Eng., Birla Inst. of Technol., Ranchi
Volume
16
Issue
4
fYear
2008
Firstpage
909
Lastpage
919
Abstract
This paper employs a wavelet multiresolution analysis (MRA) along with the adaptive-network-based fuzzy inference system to overcome the difficulties associated with conventional voltage- and current-based measurements for transmission-line fault location algorithms, due to the effect of factors such as fault inception angle, fault impedance, and fault distance. This proposed approach is different from conventional algorithms that are based on deterministic computations on a well-defined model to be protected, employing wavelet transform together with intelligent computational techniques, such as the fuzzy inference system (FIS), adaptive neurofuzzy inference system (ANFIS), and artificial neural network (ANN) in order to incorporate expert evaluation so as to extract important features from wavelet MRA coefficients for obtaining coherent conclusions regarding fault location. A comparative study establishes that the ANFIS approach has superiority over ANN- and FIS-based approaches for the location of line faults. In addition, the efficacy of the ANFIS is validated through the Monte Carlo simulation for incorporating the stochastic nature of fault occurrence in practical systems. Thus, this ANFIS-based digital relay can be used as an effective tool for real-time digital relaying purposes.
Keywords
Monte Carlo methods; fault location; fuzzy neural nets; inference mechanisms; power engineering computing; power transmission faults; wavelet transforms; ANFIS; ANN; Monte Carlo simulation; adaptive neurofuzzy inference system; adaptive-network-based fuzzy inference system; artificial neural network; current-based measurements; fault distance; fault impedance; fault inception angle; faults location; real-time digital relaying purposes; transmission lines; wavelet multiresolution analysis; Adaptive neurofuzzy inference system (ANFIS); Chi-Square test; Monte Carlo Simulation; Monte Carlo simulation (MCS); Stochastic fault location; Wavelet transform; adaptive-neuro-fuzzy interference system (ANFIS); artificial neural network (ANN); chi-square test; fault location; fuzzy inference system (FIS); fuzzy interference system (FIS); multi resolution analysis (MRA); multiresolution analysis (MRA); stochastic fault location; wavelet transform;
fLanguage
English
Journal_Title
Fuzzy Systems, IEEE Transactions on
Publisher
ieee
ISSN
1063-6706
Type
jour
DOI
10.1109/TFUZZ.2008.924210
Filename
4498424
Link To Document