• DocumentCode
    1166513
  • Title

    Early Detection of Excessive Coil Vibration in High-Voltage Rotating Electric Machines

  • Author

    Nagano, S. ; Tari, M. ; Nakano, M. ; Ito, K. ; Uto, Y.

  • Author_Institution
    Keihin Product Operations Toshiba Corporation
  • Issue
    6
  • fYear
    1982
  • fDate
    6/1/1982 12:00:00 AM
  • Firstpage
    1551
  • Lastpage
    1560
  • Abstract
    A safe and effective method of measuring stator end-winding vibrations of rotating electrical machinery and a vibration monitor are described. The method adopted is to measure electromagnetic vibration of the end-winding generating high voltage during operation. Measurements are obtained by piezoelectric pickups attached to end-winding surfaces. This method is often applied to measure vibration at other points, but it is difficult to effectively and safely measure end-winding vibration in the presence of high voltage and large current.
  • Keywords
    Coils; Current measurement; Electric machines; Electric variables measurement; Electromagnetic measurements; Machinery; Rotation measurement; Stators; Vibration measurement; Voltage;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1982.317204
  • Filename
    4111491