Early Detection of Excessive Coil Vibration in High-Voltage Rotating Electric Machines
Author
Nagano, S. ; Tari, M. ; Nakano, M. ; Ito, K. ; Uto, Y.
Author_Institution
Keihin Product Operations Toshiba Corporation
Issue
6
fYear
1982
fDate
6/1/1982 12:00:00 AM
Firstpage
1551
Lastpage
1560
Abstract
A safe and effective method of measuring stator end-winding vibrations of rotating electrical machinery and a vibration monitor are described. The method adopted is to measure electromagnetic vibration of the end-winding generating high voltage during operation. Measurements are obtained by piezoelectric pickups attached to end-winding surfaces. This method is often applied to measure vibration at other points, but it is difficult to effectively and safely measure end-winding vibration in the presence of high voltage and large current.