• DocumentCode
    117054
  • Title

    Notice of Violation of IEEE Publication Principles
    Remote patient monitoring system for rural population using ultra low power embedded system

  • Author

    Navaneethakrishnan, S. ; Mahendar, R.

  • Author_Institution
    Sri Eshwar Coll. of Eng., Coimbatore, India
  • fYear
    2014
  • fDate
    3-5 Jan. 2014
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    Notice of Violation of IEEE Publication Principles

    ???Remote Patient Monitoring System for Rural Population Using Ultra Low Power Embedded System???
    by S. Navaneethakrishnan, R. Mahendar
    in the Proceedings of the International Conference on Computer Communication and Informatics (ICCCI), January 2014.

    After careful and considered review of the content and authorship of this paper by a duly constituted expert committee, this paper has been found to be in violation of IEEE???s Publication Principles.

    This paper contains duplicated material from the paper cited below. The original text was copied without attribution (including appropriate references to the original author(s) and/or paper title) and without permission.

    ???Development of Cardiac Prescreening Device for Rural Population Using Ultralow-Power Embedded System???
    by Subhamoy Mandal, Kausik Basak, K.M. Mandana, Ajoy K. Ray, Jyotirmoy Chatterjee, Manjunatha Mahadevappa,
    IEEE Transactions on Biomedical Engineering, Vol 58, No 3, March 2011, pp. 745-749

    This paper proposed a prototype that analyses various Bio-medical parameters like temperature and blood pressure and heartbeat obtained from the sensors used & with the help of a MSP430- microcontroller, all the parameters obtained are displayed on an LCD screen. Based on the parameters obtained the patient is continuously monitored and if in case of any critical mishap when the parameters go out of a particular range then it is prevented by the care system attached to the Patient Monitoring System. The primary function of this system is to sense the temperature and heartbeat of the patient and sensed data is sent to the embedded processor port. The processor is programmed to continue monitor the data and send GSM module is used mobile message display and the actuation signals to patient care system.
  • Keywords
    cellular radio; embedded systems; medical signal processing; microcontrollers; patient care; GSM module; Global System for Mobile Communications; LCD screen; MSP430 microcontroller; actuation signals; bio-medical parameters; blood pressure; heartbeat; liquid crystal display; mobile message display; patient care system; remote patient monitoring system; rural population; temperature; ultra low power embedded system; Biomedical monitoring; Heart beat; Medical services; Microcontrollers; Monitoring; Temperature sensors; GSM module; MSP-430microcontroller; bio signals; sensors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Computer Communication and Informatics (ICCCI), 2014 International Conference on
  • Conference_Location
    Coimbatore
  • Print_ISBN
    978-1-4799-2353-3
  • Type

    conf

  • DOI
    10.1109/ICCCI.2014.6921798
  • Filename
    6921798