DocumentCode
1177095
Title
Electroquasistatic Analysis of the Gas Insulated Line for the ITER Neutral Beam Injector
Author
Bettini, P. ; Specogna, R. ; Trevisan, F.
Author_Institution
Dip. di Ing. Elettr., Univ. degli Studi di Udine, Udine
Volume
45
Issue
3
fYear
2009
fDate
3/1/2009 12:00:00 AM
Firstpage
996
Lastpage
999
Abstract
In this paper, we formulate an electroquasistatic problem according to the discrete geometric approach. As an application, the transient behavior of the gas insulated transmission line for the ITER neutral beam injector system is analyzed.
Keywords
Tokamak devices; fusion reactor ignition; gas insulated transmission lines; geometry; plasma beam injection heating; transients; ITER neutral beam injector system; discrete geometric method; electroquasistatic analysis; gas insulated transmission line; transient behaviour; Cell´s method; FIT; ITER; NBI; discrete geometric approach; electroquasistatics; high voltage applications;
fLanguage
English
Journal_Title
Magnetics, IEEE Transactions on
Publisher
ieee
ISSN
0018-9464
Type
jour
DOI
10.1109/TMAG.2009.2012538
Filename
4787412
Link To Document