DocumentCode
1186422
Title
Reliability assessment of a gas microsensor
Author
Büttner, Jörg ; Huber, Norbert ; Bruns, Michael ; Kraft, Oliver
Author_Institution
Inst. for Mater. Res. (IMF) II, Forschungszentrum Karlsruhe, Germany
Volume
4
Issue
3
fYear
2004
Firstpage
549
Lastpage
555
Abstract
To ensure mechanical reliability of a gas microsensor based on a ceramic substrate, statistically based fracture mechanics have been employed. After thermomechanical finite element simulations have been performed, failure probabilities are calculated by a statistical analysis using the postprocessor STAU. It is shown that varying packaging designs influence the stress and temperature distribution considerably. The most reliable design accounts for this factor and the sensor is mounted just by bonding wires. Thus, energy consumption of the sensor is also significantly reduced.
Keywords
ceramics; failure analysis; finite element analysis; fracture mechanics; gas sensors; microsensors; statistical analysis; STAU; ceramic substrate; failure probabilities; fracture mechanics; gas microsensor; mechanical reliability; packaging designs; reliability assessment; reliable design; statistical analysis; stress distribution; temperature distribution; thermomechanical finite element simulations; Analytical models; Ceramics; Finite element methods; Microsensors; Packaging; Probability; Statistical analysis; Temperature distribution; Thermal stresses; Thermomechanical processes;
fLanguage
English
Journal_Title
Device and Materials Reliability, IEEE Transactions on
Publisher
ieee
ISSN
1530-4388
Type
jour
DOI
10.1109/TDMR.2004.836167
Filename
1369219
Link To Document