• DocumentCode
    1194728
  • Title

    Should I Select a Service Factor Motor?

  • Author

    Merrill, Edgar F.

  • Author_Institution
    Heavy Industry Motor Division, Westinghouse Electric Corporation, P. O. Box 277, Round Rock, TX 78664.
  • Issue
    5
  • fYear
    1981
  • Firstpage
    458
  • Lastpage
    462
  • Abstract
    The selection of a motor having a 1.15 service factor to a 1.0-service factor motor of the next larger horsepower is compared. This comparison includes first cost, losses, temperature distribution, efficiency, torque performance, and expected life of the alternate selections. In most cases, the larger 1.0-service factor machine is shown to be the preferred selection.
  • Keywords
    AC motors; Induction generators; Induction motors; Insulation; Manufacturing; Synchronous motors; Temperature; Testing; Torque; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.1981.4503982
  • Filename