DocumentCode
1208525
Title
Capacitance Level Gauge for Pressurizers of Pressurized Water Reactor Plants
Author
Gernert, William
Author_Institution
Bettis Atomic Power Div., Westinghouse Electric Corp., Pittsburgh, Pa.
Volume
5
Issue
2
fYear
1958
Firstpage
50
Lastpage
53
Abstract
The pressure of a pressurized water nuclear power plant is maintained by heating water to saturation temperature in a vessel partially filled with water. The water level in this vessel, the pressurizer, must be monitored for safe plant operation. This paper describes the application of a well-known principle of liquid level measurement to this problem. The unusual operating conditions made the development of the device difficult.
Keywords
Capacitance; Ceramics; Dielectric materials; Electrodes; Flanges; Inductors; Insulation; Probes; Reactor instrumentation; Steel;
fLanguage
English
Journal_Title
Nuclear Science, IRE Transactions on
Publisher
ieee
ISSN
0096-2015
Type
jour
DOI
10.1109/TNS2.1958.4315614
Filename
4315614
Link To Document