Abstract
Pulsatile flow waveforms in the dog femoral artery and abdominal aorta were derived from measurements of pressure before and after a brief vessel occlusion. Derived flows compared favorably with directly measured flows in the abdominal aorta, less so in the femoral artery. Possible sources of deviations are discussed.
Keywords
Abdomen; Arteries; Electromagnetic measurements; Fluid flow measurement; Impedance; Pressure measurement; Probes; Pulse measurements; Reflection; Surgery; Animals; Aorta, Abdominal; Blood Pressure; Dogs; Femoral Artery; Regional Blood Flow;