    Quantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy

  • Author

    Tsui, B.M.W. ; Zhao, X.D. ; Gregoriou, G.K. ; Lalush, D.S. ; Frey, E.C. ; Johnston, R.E. ; McCartney, W.H.

  • Author_Institution
    Dept. of Biomed. Eng., North Carolina Univ., Chapel Hill, NC, USA
  • Volume
    41
  • Issue
    6
  • fYear
    1994
  • Firstpage
    2838
  • Lastpage
    2844
  • Abstract
    Patient anatomy has complicated effects on cardiac SPECT images. The authors investigated reconstruction methods which substantially reduced these effects for improved image quality. A 3D mathematical cardiac-torso (MCAT) phantom which models the anatomical structures in the thorax region were used in the study. The phantom was modified to simulate variations in patient anatomy including regions of natural thinning along the myocardium, body size, diaphragmatic shape, gender, and size and shape of breasts for female patients. Distributions of attenuation coefficients and Tl-201 uptake in different organs in a normal patient were also simulated. Emission projection data were generated from the phantoms including effects of attenuation and detector response. The authors have observed the attenuation-induced artifacts caused by patient anatomy in the conventional FBP reconstructed images. Accurate attenuation compensation using iterative reconstruction algorithms and attenuation maps substantially reduced the image artifacts and improved quantitative accuracy. The authors conclude that reconstruction methods which accurately compensate for nonuniform attenuation can substantially reduce image degradation caused by variations in patient anatomy in cardiac SPECT.<>
  • Keywords
    image reconstruction; medical image processing; single photon emission computed tomography; 3D mathematical cardiac-torso phantom; Tl; Tl-201 uptake; attenuation coefficients distributions; breasts; emission projection data; female patients; medical diagnostic imaging; natural thinning regions; nuclear medicine; organs; patient anatomy; quantitative cardiac SPECT reconstruction; reduced image degradation; Anatomical structure; Anatomy; Attenuation; Image quality; Image reconstruction; Imaging phantoms; Mathematical model; Reconstruction algorithms; Shape; Thorax;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.340655
  • Filename
    340655