DocumentCode
1218229
Title
Comparisons of lesion detectability in ultrasound images acquired using time-shift compensation and spatial compounding
Author
Lacefield, James C. ; Pilkington, Wayne C. ; Waag, Robert C.
Author_Institution
Dept. of Electr. Eng. & Comput. Eng. & Med. Biophys., Univ. of Western Ontario, London, Ont., Canada
Volume
51
Issue
12
fYear
2004
Firstpage
1649
Lastpage
1659
Abstract
The effects of aberration, time-shift compensation, and spatial compounding on the discrimination of positive-contrast lesions in ultrasound b-scan images are investigated using a two-dimensional (2-D) array system and tissue-mimicking phantoms. Images were acquired within an 8.8/spl times/12-mm/sup 2/ field of view centered on one of four statistically similar 4-mm diameter spherical lesions. Each lesion was imaged in four planes offset by successive 45/spl deg/ rotations about the central scan line. Images of the lesions were acquired using conventional geometric focusing through a water path, geometric focusing through a 35-mm thick distributed aberration phantom, and time-shift compensated transmit and receive focusing through the aberration phantom. The views of each lesion were averaged to form sets of water path, aberrated, and time-shift compensated 4:1 compound images and 16:1 compound images. The contrast ratio and detectability index of each image were computed to assess lesion differentiation. In the presence of aberration representative of breast or abdominal wall tissue, time-shift compensation provided statistically significant improvements of contrast ratio but did not consistently affect the detectability index, and spatial compounding significantly increased the detectability index but did not alter the contrast ratio. Time-shift compensation and spatial compounding thus provide complementary benefits to lesion detection.
Keywords
biomedical ultrasonics; phantoms; ultrasonic imaging; 35 mm; 4 mm; abdominal wall tissue; aberration phantom; conventional geometric focusing; lesion detectability; spatial compounding; spherical lesions; time shift compensation; tissue mimicking phantoms; two-dimensional array system; ultrasound images; Abdomen; Acoustic beams; Acoustic imaging; Acoustic pulses; Acoustic signal detection; Breast; Focusing; Imaging phantoms; Lesions; Ultrasonic imaging; Algorithms; Breast Neoplasms; Computer Simulation; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Phantoms, Imaging; Reproducibility of Results; Sensitivity and Specificity; Time Factors; Ultrasonography, Mammary;
fLanguage
English
Journal_Title
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher
ieee
ISSN
0885-3010
Type
jour
DOI
10.1109/TUFFC.2004.1386682
Filename
1386682
Link To Document