DocumentCode
1225066
Title
Effect of Load Distribution on the Voltage Drop and the Luminance Variation in an AC-PDP
Author
Kim, Jin-Sung ; Lee, Hyuk-Jae
Author_Institution
Seoul Nat. Univ., Seoul
Volume
28
Issue
10
fYear
2007
Firstpage
896
Lastpage
898
Abstract
In an alternating-current plasma display panel (AC-PDP), the displayed luminance of a cell is often different from the target luminance because the luminance is affected by the voltage applied to the cell, which is determined by the distribution of on-cells. In this letter, a circuit model of an AC-PDP is presented, and the effect of load distribution on the applied voltage is analyzed with the circuit model. The analytical results are validated by the experimental measurements with an AC-PDP set.
Keywords
brightness; electric potential; plasma displays; alternating-current plasma display panel; applied voltage load distribution; cell displayed luminance; circuit model; luminance variation; on-cell distribution; target luminance; voltage drop; Circuit analysis; Degradation; Electrodes; Helium; Image analysis; Plasma displays; Plasma measurements; Plasma temperature; Resistors; Voltage; Load effect; luminance variation; plasma display panel (PDP); voltage variation;
fLanguage
English
Journal_Title
Electron Device Letters, IEEE
Publisher
ieee
ISSN
0741-3106
Type
jour
DOI
10.1109/LED.2007.905957
Filename
4317661