  • Title

    An Algorithm for Volume Estimation Based on Polyhedral Approxi mation

  • Author

    Cook, Larry T. ; Cook, P.Nong ; Lee, Kyo Rak ; Batnitzky, Solomon ; Wong, Bert Y.S. ; Fritz, Steven L. ; Ophir, Jonathan ; Dwyer, Samuel J. ; Bigongiari, Lawrence R. ; Templeton, Arch W.

  • Author_Institution
    Department of Diagnostic Radiology, University of Kansas Medical Center
  • Issue
    9
  • fYear
    1980
  • Firstpage
    493
  • Lastpage
    500
  • Abstract
    A volume algorithm is established which uses the data generated by computed tomography (CT) or ultrasound scans. The algorithm is based on a polyhedral reconstruction of an object of interest. Phantom studies indicate that the algorithm calculated volume is accurate within 3 percent. In a controlled clinical experiment on a laboratory animal, the algorithm calculated volume showed a maximum error of about 5 percent. In less controllable applications to human clinical data, volume calculations showed variations ranging up to 16 percent.
  • Keywords
    Biomedical imaging; Bit error rate; Cities and towns; Computed tomography; Image edge detection; Imaging phantoms; Liver; Medical diagnostic imaging; Shape; Surface reconstruction; Animals; Anthropometry; Dogs; Humans; Mathematics; Models, Anatomic; Models, Biological; Tomography, X-Ray Computed; Ultrasonography;