• DocumentCode
    1226633
  • Title

    Development of a 40-year design life severe duty motor

  • Author

    Stiffler, Walter G. ; Bell, Sidney

  • Author_Institution
    Reliance Electr. Co., Cleveland, OH, USA
  • Volume
    25
  • Issue
    5
  • fYear
    1989
  • Firstpage
    881
  • Lastpage
    882
  • Abstract
    The factors that lead to motor failure are considered, and an analysis of those components most affected by insulation design is presented. The insulation design factors considered are: enclosure, rotating elements, electrical winding, materials, and the manufacturing processes used. The selection of proper insulation to protect the winding from premature failure for round-wire random windings is discussed
  • Keywords
    electric motors; machine insulation; machine windings; electrical winding; enclosure; insulation design; manufacturing processes; motor failure; rotating elements; round-wire random windings; severe duty motor; Cable insulation; Dielectrics and electrical insulation; Electric motors; Hysteresis motors; Insulation testing; Resistance heating; Seals; System testing; Thermal stresses; Wire;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/28.41252
  • Filename
    41252