DocumentCode
1231536
Title
An Aerospace Dilemma: The Incompatibility of Electromagnetics and Necessary Pyrotechnic Devices
Author
Milano, A.F. ; Colin, R.J.
Author_Institution
Hughes Aircraft Company Culver City, California
Issue
2
fYear
1965
fDate
6/1/1965 12:00:00 AM
Firstpage
514
Lastpage
522
Abstract
A perfect field safety record continues from these developments: 1) Determination of the threshold-energy (system safety) rating of several pyrotechnic devices via an advanced pulse technique. A 1 ampere, 1 watt power rating is incomplete and has no direct relationship to threshold energy levels. 2) Evolvement of an unconventional system circuit and logic design. 3) Continued field safety assessment using the Hughes stray energy monitor. It provides a simple, objective go, no-go indication of system safety.
Keywords
Aerospace safety; Air safety; Electromagnetic devices; Electromagnetic heating; Explosives; Fires; Instruments; Safety devices; Testing; Vehicles;
fLanguage
English
Journal_Title
Aerospace, IEEE Transactions on
Publisher
ieee
ISSN
0536-1516
Type
jour
DOI
10.1109/TA.1965.4319845
Filename
4319845
Link To Document