• DocumentCode
    1252837
  • Title

    Measuring RF and microwave permittivities of adult rice weevils

  • Author

    Nelson, Stuart O. ; Bartley, Philip G., Jr. ; Lawrence, Kurt C.

  • Author_Institution
    Russell Res. Center, Agric. Res. Service, Athens, GA, USA
  • Volume
    46
  • Issue
    4
  • fYear
    1997
  • fDate
    8/1/1997 12:00:00 AM
  • Firstpage
    941
  • Lastpage
    946
  • Abstract
    The dielectric permittivities of bulk samples of adult rice weevils were measured over the frequency range from 0.2 GHz to 20 GHz at temperatures from 10°C to 65°C with an open-ended coaxial-line probe, network analyzer, and a sample temperature control assembly designed for the measurements. Repeated measurements were highly variable, because mean sample bulk densities did not accurately reflect effective densities of the bulk rice weevil samples in the small volume of sample sensed by the coaxial-line probe. Density corrections based on earlier permittivity measurements on bulk rice weevil samples at 9.4 GHz, at known sample densities, removed much of the variability. The corrections utilized the linear relationship between the cube root of the dielectric constant and bulk density, which permitted estimates of the weevil body permittivities to be obtained with the Landau, Lifshitz, and Looyenga equation for dielectric mixtures. Estimated dielectric constants and loss factors of the insects from averages of seven different measurement sequences are presented graphically for temperatures from 15°C to 65°C
  • Keywords
    agriculture; coaxial cables; dielectric loss measurement; microwave measurement; network analysers; permittivity measurement; temperature control; 0.2 to 20 GHz; 10 to 65 C; 15 to 65 C; 9.4 GHz; Landau equation; Lifshitz equation; Looyenga equation; Sitophilus oryzae; bulk density; bulk samples; coaxial-line probe; density correction; dielectric constant; dielectric constants; dielectric mixtures; effective densities; insects; loss factors; mean sample bulk densities; microwave permittivities; network analyzer; open-ended coaxial-line probe; permittivity measurements; rice weevils; sample temperature control assembly; Coaxial components; Dielectric constant; Dielectric loss measurement; Dielectric measurements; Frequency measurement; Microwave measurements; Permittivity measurement; Probes; Radio frequency; Temperature distribution;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/19.650805
  • Filename
    650805