DocumentCode
1268519
Title
Effect of full voltage starting on the windings of squirrel-cage induction motors
Author
Rylander, J.L.
Author_Institution
Westinghouse Electric & Manufacturing Co., East Pittsburgh, Pa.
Volume
44
Issue
2
fYear
1925
Firstpage
115
Lastpage
121
Abstract
This paper discusses the effect on the windings when starting squirrel-cage induction motors with full voltage. The data is presented in four groups: namely, (1) Special tests made with a vibrograph instrument on a 60 h. p. and a 500 h. p. induction motor: (2) Observation tests made on a number of motors when starting with full voltage: (3) The condition of some windings which failed in service: (4) Formulas which show the main factors involved in the bracing of induction motors. Induction motor coil bracing in general is discussed.
fLanguage
English
Journal_Title
A.I.E.E., Journal of the
Publisher
ieee
ISSN
0095-9804
Type
jour
DOI
10.1109/JAIEE.1925.6536158
Filename
6536158
Link To Document