DocumentCode
1269230
Title
Registration of three-dimensional cardiac catheter models to single-plane fluoroscopic images
Author
Meyer, Scott A. ; Wolf, Patrick D.
Author_Institution
Dept. of Biomed. Eng., Duke Univ., Durham, NC, USA
Volume
46
Issue
12
fYear
1999
Firstpage
1471
Lastpage
1479
Abstract
Transvenous cardiac procedures require accurate positioning of catheters within the geometrically complex cavities of the heart. Recently, nonfluoroscopic catheter tracking technologies have been developed to quantitate the (degrees-of-freedom) three-dimensional positions of intracardiac catheters. This paper presents a projection-Procrustes method to register an animated three-dimensional (3-D) model of multiple intracardiac catheters with a single-plane fluoroscopic image. Applying the computed transformation to the catheter coordinates enables the animated 3-D model of the catheters to be viewed from the same perspective as the fluoroscopic image. Mathematical simulations show that the computed transformation parameters are sensitive to both the position errors in the 3-D catheter coordinates and to the spatial distribution of the catheter-mounted transducers. Simulations with a realistic geometric model of three catheters with four transducers per catheter showed an angular error of 1.91°±0.27° for 3-D catheter position errors of 2.0 mm. An in vitro experiment demonstrated the feasibility of the method using a water tank phantom of three catheters and fluoroscopic images taken over an 80° range. The mean angular error was 0.61°±0.48°. The results of this study indicate that the projection-Procrustes method is a useful tool for registering 3-D catheter tracking models to single-plane fluoroscopic images.
Keywords
cardiology; diagnostic radiography; image registration; medical image processing; accurate catheter positioning; angular error; catheter coordinates computed transformation; catheter-mounted transducers; geometrically complex cavities; heart; in vitro experiment; multiple intracardiac catheters; nonfluoroscopic catheter tracking technologies; projection-Procrustes method; realistic geometric model; single-plane fluoroscopic images; spatial distribution; three-dimensional cardiac catheter models registration; transvenous cardiac procedures; water tank phantom; Animation; Catheters; Computational modeling; Distributed computing; Heart; Imaging phantoms; In vitro; Registers; Solid modeling; Transducers; Algorithms; Fluoroscopy; Heart Catheterization; Models, Anatomic; Models, Statistical; Models, Theoretical; Transducers;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/10.804575
Filename
804575
Link To Document