• DocumentCode
    1270638
  • Title

    Switching Strategies for Fault Tolerant Operation of Single DC-link Dual Converters

  • Author

    Restrepo, Jose A. ; Berzoy, Alberto ; Ginart, Antonio E. ; Aller, Jose M. ; Harley, Ronald G. ; Habetler, Thomas G.

  • Author_Institution
    Univ. Simon Bolivar, Caracas, Venezuela
  • Volume
    27
  • Issue
    2
  • fYear
    2012
  • Firstpage
    509
  • Lastpage
    518
  • Abstract
    This paper proposes a method that allows the operation with direct torque control under incipient faults of the power switching devices in single dc-link dual inverters. Once the fault onset of the switching device is detected, the troubled devices are put under trigger suppression to regain operation. The proposed control algorithm makes use of additional states, termed opportunistic states, to maintain control of the induction machine. Simulations and experimental results confirm the capabilities of the technique for up to six devices under trigger suppression.
  • Keywords
    asynchronous machines; fault tolerance; invertors; machine control; switching convertors; torque control; direct torque control; fault tolerant operation; induction machine; power switching devices; single DC-link dual converters; single DC-link dual inverters; switching converters; trigger suppression; Aerospace electronics; Fault tolerance; Fault tolerant systems; Stators; Switches; Topology; Windings; AC motor drives; drives; fault tolerance; inverters;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2011.2161639
  • Filename
    5951785