DocumentCode
1270638
Title
Switching Strategies for Fault Tolerant Operation of Single DC-link Dual Converters
Author
Restrepo, Jose A. ; Berzoy, Alberto ; Ginart, Antonio E. ; Aller, Jose M. ; Harley, Ronald G. ; Habetler, Thomas G.
Author_Institution
Univ. Simon Bolivar, Caracas, Venezuela
Volume
27
Issue
2
fYear
2012
Firstpage
509
Lastpage
518
Abstract
This paper proposes a method that allows the operation with direct torque control under incipient faults of the power switching devices in single dc-link dual inverters. Once the fault onset of the switching device is detected, the troubled devices are put under trigger suppression to regain operation. The proposed control algorithm makes use of additional states, termed opportunistic states, to maintain control of the induction machine. Simulations and experimental results confirm the capabilities of the technique for up to six devices under trigger suppression.
Keywords
asynchronous machines; fault tolerance; invertors; machine control; switching convertors; torque control; direct torque control; fault tolerant operation; induction machine; power switching devices; single DC-link dual converters; single DC-link dual inverters; switching converters; trigger suppression; Aerospace electronics; Fault tolerance; Fault tolerant systems; Stators; Switches; Topology; Windings; AC motor drives; drives; fault tolerance; inverters;
fLanguage
English
Journal_Title
Power Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0885-8993
Type
jour
DOI
10.1109/TPEL.2011.2161639
Filename
5951785