• DocumentCode
    1271163
  • Title

    Some features and improvements on the high-voltage wattmeter

  • Author

    Carroll

  • Author_Institution
    Seattle, Washington
  • Volume
    45
  • Issue
    1
  • fYear
    1926
  • Firstpage
    61
  • Lastpage
    62
  • Abstract
    R. W. Sorensen: When I first saw the diagram of connections shown in this paper I was awed by the apparent amount of large apparatus necessary to construct such a wattmeter. However, I have had the opportunity to stop at Professor Ryan´s laboratory and became acquainted with the equipment described in this paper. An acquaintance with the equipment eliminated the impression of bigness which I had received from the diagram and which was perhaps due partly to the high voltages which the equipment will measure. In place of this impression I received a definite picture of the cleverness exhibited by Mr. Carroll and Professor Ryan in handling this problem. For example, the transformer of three windings and a split core, which seems in the diagram to be so large, is actually very small, in fact, it can easily be held in one hand.
  • fLanguage
    English
  • Journal_Title
    A.I.E.E., Journal of the
  • Publisher
    ieee
  • ISSN
    0095-9804
  • Type

    jour

  • DOI
    10.1109/JAIEE.1926.6536610
  • Filename
    6536610