• DocumentCode
    1273432
  • Title

    Six-Phase Supply Feasibility Using a PM Fractional-Slot Dual Winding Machine

  • Author

    Barcaro, Massimo ; Bianchi, Nicola ; Magnussen, F.

  • Author_Institution
    Dept. of Electr. Eng., Univ. of Padova, Padova, Italy
  • Volume
    47
  • Issue
    5
  • fYear
    2011
  • Firstpage
    2042
  • Lastpage
    2050
  • Abstract
    The growing interest in fault-tolerant drives requires new solutions avoiding the adoption of custom and expensive configurations. The machine with a dual three-phase winding is an interesting candidate. It is provided with two windings, each of them fed by one converter of half power. With a proper mechanical and electrical arrangement, the machine can be exactly a six-phase machine, obtaining higher performance during healthy conditions. In the event of a fault, one of the two three-phase windings (the faulty one) is disconnected, and the machine is operated by means of the healthy winding only. This paper analyzes the feasibility of this dual winding configuration applied to a nonoverlapped-coil fractional-slot winding permanent-magnet machine. The star of slots is applied to highlight the proper winding candidates. The more interesting windings are deeply analyzed.
  • Keywords
    fault diagnosis; machine windings; permanent magnet machines; PM fractional-slot dual-winding machine; converter; fault-tolerant drives; machine health conditions; nonoverlapped-coil fractional-slot winding permanent magnet machine; six-phase supply feasibility; three-phase winding; Coils; Fault tolerance; Fault tolerant systems; Harmonic analysis; Motor drives; Torque; Windings; Brushless motors; PM motors; fault tolerance; permanent-magnet (PM) machines;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2011.2161859
  • Filename
    5954176