• DocumentCode
    1280698
  • Title

    Online fault-detecting scheme of an inverter-fed permanent magnet synchronous motor under stator winding shorted turn and inverter switch open

  • Author

    Kim, Kwan-Ho ; Gu, Bon-Gwan ; Jung, In-Seok

  • Author_Institution
    Dept. of Electr. Eng., Seoul Nat. Univ. of Sci. & Technol., Seoul, South Korea
  • Volume
    5
  • Issue
    6
  • fYear
    2011
  • fDate
    7/1/2011 12:00:00 AM
  • Firstpage
    529
  • Lastpage
    539
  • Abstract
    To detect faults in an inverter-fed permanent magnet synchronous motor drive under the circumstance having faults in a stator winding and inverter switch, an online basis fault-detecting scheme during motor operation is presented. The proposed scheme is achieved by monitoring the second-order harmonic component in q-axis current and the fault is detected by comparing these components with those in normal conditions. The non-fault harmonic data in an arbitrary operating condition are determined using the linear interpolation method with several sample harmonic data pre-measured in the stage of the initial drive setup. Once the fault is detected, the operating mode is changed to identify a fault source using the phase current waveform. To verify the effectiveness of the proposed fault detecting scheme, a test motor to allow inter-turn short in the stator winding has been built. The entire control system including harmonic analysis and fault detecting algorithm is implemented using digital signal processor TMS320F28335. Without requiring an additional hardware, the fault can be effectively detected by the proposed scheme during operation so long as the steady-state condition is satisfied.
  • Keywords
    fault diagnosis; interpolation; invertors; permanent magnet motors; synchronous motor drives; arbitrary operating condition; control system; digital signal processor TMS320F28335; fault source; g-axis current; harmonic analysis; inverter switch open; inverter-fed permanent magnet synchronous motor drive; linear interpolation method; motor operation; nonfault harmonic data; online fault-detecting scheme; phase current waveform; second-order harmonic component; stator winding shorted turn;
  • fLanguage
    English
  • Journal_Title
    Electric Power Applications, IET
  • Publisher
    iet
  • ISSN
    1751-8660
  • Type

    jour

  • DOI
    10.1049/iet-epa.2010.0272
  • Filename
    5960733