• DocumentCode
    1286994
  • Title

    Compact On-Chip Microtensile Tester With Prehensile Grip Mechanism

  • Author

    Hazra, Siddharth S. ; Baker, Michael S. ; Beuth, Jack L. ; De Boer, Maarten P.

  • Author_Institution
    Dept. of Mech. Eng., Carnegie Mellon Univ., Pittsburgh, PA, USA
  • Volume
    20
  • Issue
    4
  • fYear
    2011
  • Firstpage
    1043
  • Lastpage
    1053
  • Abstract
    Accurate measurement of material strength at small scales is of critical importance for the design and manufacture of reliable micro- and nanoscale devices. Many materials of interest, e.g., polycrystalline silicon (polysilicon) and silicon carbide, are brittle, with statistical strength distributions. Therefore, strength quantification requires a large number of tests accurately performed on a practical platform. Here, analysis and testing of a compact on-chip microtensile test system, recently presented in a brief communication [Hazra et al., Journal of Micromechanics & Microengineering, 2009], is expanded significantly. We present new data on strength, alignment precision, temperature distribution, compliance calibration, stiffness ratio, force calibration, and effect of monolayer film coverage. High force (up to 30 mN) is applied to a 70-μm-long freestanding tensile bar (nominally of 2 μm width and 2.25 μm height) by cooling a thermal actuator (TA) that has gripped a crosshead via a prehensile mechanism. According to finite element analysis, specimen heating is small (<; 45°C above ambient). The system features a relatively small area occupied on the chip (500 × 700 μm2); excellent alignment resulting in in-plane and out-of-plane stress gradients of 2.2% and 1.5%, respectively, no sensitivity to residual stress or to cross-sectional shape, and high strain resolution (2.3 ×10-4). A compliance calibration factor, obtained from finite element analysis, is used to convert measured fracture displacement to fracture strain. The grip mechanism must be much stiffer than the tensile bar. A value of 6.1 is determined for this stiffness ratio. We show that the TA acts as a nonlinear spring that can be modeled to determine the applied force. Assuming a value of Young´s modulus E = 164 GPa, we find a characteristic strength of 2.45 GPa, with a Weibull modulus of 12.04, reflecting a- - sample size of N = 34 polysilicon microtensile bars.
  • Keywords
    Weibull distribution; Young´s modulus; calibration; finite element analysis; fracture; silicon; silicon compounds; tensile testing; Si; SiC; Weibull modulus; Young´s modulus; alignment precision; compact on-chip microtensile tester; compliance calibration; cross-sectional shape; finite element analysis; force calibration; fracture displacement; fracture strain; material strength; microscale devices; monolayer film coverage; nanoscale devices; polycrystalline silicon; prehensile grip mechanism; pressure 164 GPa; pressure 2.45 GPa; residual stress; silicon carbide; statistical strength distributions; stiffness ratio; temperature distribution; Actuators; Force; Grippers; Leg; Strain; Stress; System-on-a-chip; High throughput; microelectromechanical systems (MEMS); on chip; polysilicon strength; uniaxial tensile tester;
  • fLanguage
    English
  • Journal_Title
    Microelectromechanical Systems, Journal of
  • Publisher
    ieee
  • ISSN
    1057-7157
  • Type

    jour

  • DOI
    10.1109/JMEMS.2011.2159097
  • Filename
    5968408