DocumentCode
1287353
Title
An International comparison of voltage-transformer calibrations to 350 kv
Author
Harris, F.K. ; Sze, W.C. ; Kusters, N.L. ; Petersons, O. ; Moore, W.J.M.
Author_Institution
National Bureau of Standards, Washington, D. C.
Volume
83
Issue
70
fYear
1964
Firstpage
13
Lastpage
19
Abstract
IN JUNE 1960, the Hydro-Electric Power Commission of Ontario inquired whether the United States National Bureau of Standards (NBS) in Washington could measure for them the ratio and phase-angle errors of a 350-kv voltage transformer then being built to their order. This request was also made at about the same time of the National Research Council of Canada (NRC) in Ottawa. Neither laboratory had, at that time, made calibration measurements on instrument transformers at this voltage level, but both had given the problem considerable thought; and it appeared that the request by Ontario Hydro afforded a unique opportunity not only to examine some of the problems involved in voltage-ratio measurements at 350 kv, but also to compare measurement results between the two national laboratories.
fLanguage
English
Journal_Title
Communication and Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0536-1532
Type
jour
DOI
10.1109/TCOME.1964.6539562
Filename
6539562
Link To Document