    Electrical conduction and dielectric breakdown characteristics of alkyl ester dielectric fluids obtained from palm kernel oil

  • Author

    Abdelmalik, A.A. ; Fothergill, J.C. ; Dodd, S.J.

  • Author_Institution
    Dept. of Eng., Univ. of Leicester, Leicester, UK
  • Volume
    19
  • Issue
    5
  • fYear
    2012
  • fDate
    10/1/2012 12:00:00 AM
  • Firstpage
    1623
  • Lastpage
    1632
  • Abstract
    Naturally occurring palm kernel oil (PKO) and its ester derivatives are being considered as sustainable alternatives to synthetic oils for use as dielectric fluids. This paper reports on their dielectric properties, which have been studied and compared to BS148 mineral oil. The low frequency complex dielectric response of the PKO and its derivatives are related to ionic conduction and electrode polarization phenomena. The purified PKO has an electrical conductivity of 3.04 × 10-12 Sm-1 at 30°C; this is 10 times lower than crude PKO but about 10 times greater than the BS148 oil. The bulk conductivity is thermally activated, activation energy = 0.47 eV, and influenced by viscosity. The ester derivatives have a higher conductivity than the PKO, which is related to ionic impurities introduced during processing. The breakdown field was measured in a bespoke cell enabling smaller volumes of oil (15 ml) than that used in ASTM D1816. The characteristic ac breakdown strength of purified PKO and is alkyl esters were found to be in the range, 41 to 43 kV/mm, which is significantly higher than the mineral oil (27 kV/mm). The results support the proposition that a dielectric fluid derived from palm kernel oil, once re-purified, may be a suitable replacement for mineral oil based fluids in HV electrical equipment.
  • Keywords
    crude oil; electric breakdown; electrical conductivity; electrodes; viscosity; ASTM D1816; BS148 mineral oil; HV electrical equipment; alkyl ester dielectric fluids; bespoke cell; crude PKO; dielectric breakdown characteristics; electrical conduction characteristics; electrical conductivity; electrode polarization phenomena; electron volt energy 0.47 eV; frequency complex dielectric response; ionic conduction phenomena; ionic impurities; palm kernel oil; purified PKO AC breakdown strength; synthetic oils; Conductivity; Dielectrics; Electric breakdown; Electrodes; Liquids; Temperature measurement; Dielectric breakdown; Dielectric liquids; Dielectric losses; Ester derivatives; Fluid flow; Weibull distributions;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2012.6311509
  • Filename