DocumentCode
1294995
Title
Sensitivity distributions of EEG and MEG measurements
Author
Malmivuo, Jaakko ; Suihko, Veikko ; Eskola, Hannu
Author_Institution
Ragnar Granit Inst., Tampere Univ. of Technol., Finland
Volume
44
Issue
3
fYear
1997
fDate
3/1/1997 12:00:00 AM
Firstpage
196
Lastpage
208
Abstract
It is generally believed that because the skull has low conductivity to electric current but is transparent to magnetic fields, the measurement sensitivity of the magnetoencephalography (MEG) in the brain region should be more concentrated than that of the electroencephalography (EEG). It is also believed that the information recorded by these techniques is very different. If this were indeed the case, it might be possible to justify the cost of MEG instrumentation which is at least 25 times higher than that of EEG instrumentation. The localization of measurement sensitivity using these techniques was evaluated quantitatively in an inhomogeneous spherical head model using a new concept called half-sensitivity volume (HSV). It is shown that the planar gradiometer has a far smaller HSV than the axial gradiometer. However, using the EEG it is possible to achieve even smaller HSVs than with whole-head planar gradiometer MEG devices. The micro-superconducting quantum interference device (SQUID) MEG device does have HSVs comparable to those of the EEG. The sensitivity distribution of planar gradiometers, however, closely resembles that of dipolar EEG leads and, therefore, the MEG and EEG record the electric activity of the brain in a very similar way.
Keywords
electroencephalography; magnetoencephalography; physiological models; EEG measurements; MEG measurements; axial gradiometer; brain electric activity; dipolar EEG leads; half-sensitivity volume; inhomogeneous spherical head model; measurement sensitivity; micro-superconducting quantum interference device; planar gradiometer; sensitivity distributions; skull; Conductivity measurement; Costs; Current measurement; Electric variables measurement; Electroencephalography; Instruments; Magnetic field measurement; Magnetoencephalography; Skull; Volume measurement; Anisotropy; Cerebral Cortex; Electric Conductivity; Electrodes; Electroencephalography; Equipment Design; Head; Humans; Magnetoencephalography; Models, Neurological; Sensitivity and Specificity; Skull;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/10.554766
Filename
554766
Link To Document