• DocumentCode
    1295702
  • Title

    Coherent image fringe contrast measurement with sensing arrays

  • Author

    Seemuller, William W.

  • Author_Institution
    Res. Inst., US Army Engr. Topographic Labs., Fort Belvoir, VA, USA
  • Issue
    3
  • fYear
    1982
  • Firstpage
    180
  • Lastpage
    184
  • Abstract
    Two methods are described for measuring interferometric fringe contrast with sensing arrays. The absence of air turbulence allows contrast to be determined quickly by measuring the intensity of the fringe pattern at phases 90° apart. The presence of turbulence requires that the peak-to-peak fringe intensity be found by sampling the fringes as they are scanned across the array. An analysis is presented showing the relation between maximum error in fringe contrast measurement and the number of samples taken. Experimental results are presented which show the effect of turbulence on fringe contrast measurement.
  • Keywords
    image sensors; light interferometry; optical variables measurement; air turbulence; coherent image fringe contrast measurement; fringe pattern; interferometric fringe contrast; light interferometry; peak-to-peak fringe intensity; Accuracy; Arrays; Computers; Correlation; Measurement uncertainty; Optical interferometry; TV;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1982.6312555
  • Filename