A voltage-doubling method for measuring the voltage dependence of compressed gas capacitors
Author
Latzel, Hans-Georg ; Leren, W.
Author_Institution
Phys.-Tech. Bundesanstalt, Braunschweig, West Germany
Issue
3
fYear
1987
Firstpage
730
Lastpage
734
Abstract
A commercially available transformer-ratio-arm capacitance bridge is used two different circuits to measure the voltage dependence of a capacitor by comparing it with a second compressed-gas capacitor, the voltage dependence of which need not be known. Measurements have been carried out at power frequency with an experimental setup for voltages up to 50 kV. A maximum uncertainty of six parts in 106 for the relative change of the capacitance was estimated.
Keywords
bridge instruments; capacitance measurement; capacitors; characteristics measurement; high-voltage techniques; 50 kV; compressed gas capacitors; transformer-ratio-arm capacitance bridge; up to 50 kV; voltage dependence; voltage measurement; voltage-doubling method; Bridge circuits; Capacitance; Capacitance measurement; Capacitors; Electrodes; Standards; Voltage measurement;