• DocumentCode
    1298123
  • Title

    Stability requirements for multiple laser diode extended range interferometry

  • Author

    Meggitt, B.T. ; Cormier, A.J.

  • Author_Institution
    Sira Ltd., Chislehurst
  • Volume
    24
  • Issue
    6
  • fYear
    1988
  • fDate
    3/17/1988 12:00:00 AM
  • Firstpage
    352
  • Lastpage
    353
  • Abstract
    The effects of wavelength instabilities on the performance of a multiwavelength heterodyne interferometer are treated theoretically in relation to a multisource system. The analysis predicts that a geometrically progressive synthetic wave set is the ideal configuration, and that an optimum number of wavelengths exists that minimises the stability requirements of the sources
  • Keywords
    distance measurement; light interferometry; measurement by laser beam; semiconductor junction lasers; stability; extended range interferometry; geometrically progressive synthetic wave set; ideal configuration; multiple laser diode; multisource system; multiwavelength heterodyne interferometer; ranging instruments; semiconductor lasers; wavelength instabilities;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • Filename
    8213