• DocumentCode
    1306480
  • Title

    System reconfiguration under open-switch faults in a doubly fed induction machine

  • Author

    Sae-Kok, W. ; Grant, D.M. ; Williams, Barry W.

  • Author_Institution
    Sch. of Electr. Eng., King Mongkut´s Inst. of Technol. Ladkrabang, Bangkok, Thailand
  • Volume
    4
  • Issue
    5
  • fYear
    2010
  • fDate
    9/1/2010 12:00:00 AM
  • Firstpage
    458
  • Lastpage
    470
  • Abstract
    The aim of this study is to present system reconfiguration for a doubly fed induction machine (DFIM) after an open-switch fault is detected in its back-to-back converters. The open-switch fault and its detection for the scheme are discussed first. System reconfiguration is applied to operate the DFIM after the fault is detected. A four-switch converter topology with dc-link midpoint connection is selected to reconfigure the system. An existing pulse-width modulation method is investigated and applied to reconfigure the system, but uncontrollable capacitor voltage drift occurs. This study proposes a technique to solve the drift problem and also improve the quality of the dc-link voltage. Its effectiveness is substantiated by both simulation and experiment.
  • Keywords
    PWM power convertors; asynchronous machines; fault diagnosis; DFIM; back-to-back converters; dc link voltage; doubly fed induction machine; fault detection; open switch faults; pulsewidth modulation method;
  • fLanguage
    English
  • Journal_Title
    Renewable Power Generation, IET
  • Publisher
    iet
  • ISSN
    1752-1416
  • Type

    jour

  • DOI
    10.1049/iet-rpg.2010.0005
  • Filename
    5559318