DocumentCode
1306480
Title
System reconfiguration under open-switch faults in a doubly fed induction machine
Author
Sae-Kok, W. ; Grant, D.M. ; Williams, Barry W.
Author_Institution
Sch. of Electr. Eng., King Mongkut´s Inst. of Technol. Ladkrabang, Bangkok, Thailand
Volume
4
Issue
5
fYear
2010
fDate
9/1/2010 12:00:00 AM
Firstpage
458
Lastpage
470
Abstract
The aim of this study is to present system reconfiguration for a doubly fed induction machine (DFIM) after an open-switch fault is detected in its back-to-back converters. The open-switch fault and its detection for the scheme are discussed first. System reconfiguration is applied to operate the DFIM after the fault is detected. A four-switch converter topology with dc-link midpoint connection is selected to reconfigure the system. An existing pulse-width modulation method is investigated and applied to reconfigure the system, but uncontrollable capacitor voltage drift occurs. This study proposes a technique to solve the drift problem and also improve the quality of the dc-link voltage. Its effectiveness is substantiated by both simulation and experiment.
Keywords
PWM power convertors; asynchronous machines; fault diagnosis; DFIM; back-to-back converters; dc link voltage; doubly fed induction machine; fault detection; open switch faults; pulsewidth modulation method;
fLanguage
English
Journal_Title
Renewable Power Generation, IET
Publisher
iet
ISSN
1752-1416
Type
jour
DOI
10.1049/iet-rpg.2010.0005
Filename
5559318
Link To Document