DocumentCode
1313072
Title
Design of a large-bore 60-T pulse magnet for Sandia National Laboratories
Author
Li, L. ; Rovang, D. ; Lesch, B. ; Pernambuco-Wise, P. ; Schneider-Muntau, H.J.
Author_Institution
Nat. High Magnetic Field Lab., Tallahassee, FL, USA
Volume
10
Issue
1
fYear
2000
fDate
3/1/2000 12:00:00 AM
Firstpage
530
Lastpage
533
Abstract
The design of a new pulsed magnet system for the generation of intense electron beams is presented. Determined by the required magnetic field profile along the axis, the magnet system consists of two coils (Coil 1 and 2) separated by a 32-mm axial gap. Each coil is energized independently. Both coils are internally reinforced with HM Zylon fiber/epoxy composite. Coil 1 made with Al-15 Glidcop wire has a bore of 110-mm diameter and is 200-mm long; it is energized by a 1.3-MJ, 13-kV capacitor bank. The magnetic field at the center of this coil is 30 T. Coil 2 made with CuNb wire has a bore diameter of 45 mm, generates 60 T with a pulse duration of 60 ms, and is powered by a 4.0-MJ, 17.7-kV capacitor bank. We present design criteria, coupling of the magnets, and normal and fault conditions during operation.
Keywords
capacitor storage; coils; electromagnets; power supplies to apparatus; 1.3 MJ; 110 mm; 13 kV; 17.7 kV; 200 mm; 30 T; 32 mm; 4 MJ; 45 mm; 60 T; 60 ms; Al-15 Glidcop wire; CuNb wire; HM Zylon fiber/epoxy composite; Sandia National Laboratories; capacitor bank; design criteria; fault conditions; large-bore 60-T pulse magnet; magnetic field; pulsed magnet system; Boring; Capacitors; Coils; Couplings; Electron beams; Magnetic fields; Magnetic separation; Power generation; Pulse generation; Wire;
fLanguage
English
Journal_Title
Applied Superconductivity, IEEE Transactions on
Publisher
ieee
ISSN
1051-8223
Type
jour
DOI
10.1109/77.828289
Filename
828289