DocumentCode
1319964
Title
Proper specification and installation of induction motors
Author
Finlay, W.R. ; Burke, K.R.
Author_Institution
Motors & Drives Div., Siemens Energy & Autom. Inc., Norwood, OH, USA
Volume
3
Issue
1
fYear
1997
Firstpage
56
Lastpage
69
Abstract
To achieve years of trouble-free operation, the proper motor for an application must be chosen. This requires that the motor be properly specified for the specific application, taking into account any special ambient conditions, performance requirements or environmental concerns. Without this, nothing else will matter. This article discusses how to determine the minimum acceptable motor for an application. It also makes recommendations for selecting additional features yielding higher protection and performance, and gives tips regarding installation and maintenance
Keywords
acoustic noise; induction motor protection; induction motors; installation; machine bearings; machine insulation; maintenance engineering; rotors; stators; ambient conditions; environmental concerns; induction motors; installation; maintenance; minimum acceptable motor; performance requirements; protection; recommendations; selection guidelines; specification; trouble-free operation; Coils; Costs; Induction motors; Plugs; Protection; Rain; Rotors; Shafts; Space heating; Water resources;