• DocumentCode
    1320065
  • Title

    Experimental Data for Locating VSM Pickup Coils and Minimizing the Image Effect

  • Author

    Lorenz, B.E. ; Graham, C.D.

  • Author_Institution
    Dept. of Electr. Eng., Widener Univ., Chester, PA, USA
  • Volume
    48
  • Issue
    11
  • fYear
    2012
  • Firstpage
    2914
  • Lastpage
    2916
  • Abstract
    From measurements of the magnetic field produced in the air gap of an electromagnet by a small permanent magnet sample, we can predict the relative sensitivity of a vibrating-sample magnetometer (VSM) for any practical location of the pickup coils. By repeating the measurements with the pole pieces removed, we can simulate the case of complete magnetic saturation (permeability μ = 1) of the pole pieces, and thus predict the relative magnitude of the image effect for any coil location. Under some conditions, a coil position can be chosen that eliminates the image effect.
  • Keywords
    coils; electromagnets; magnetic field measurement; magnetic sensors; magnetometers; permanent magnets; pick-ups; vibration measurement; VSM pickup coil location; air gap; electromagnet; image effect minimization; magnetic field measurement; magnetic saturation; permanent magnet sample; pole piece removal; vibrating-sample magnetometer; Coils; Electromagnets; Magnetic resonance imaging; Magnetometers; Permanent magnets; Permeability; Saturation magnetization; Image effect; magnetic measurements; vibrating-sample magnetometer (VSM);
  • fLanguage
    English
  • Journal_Title
    Magnetics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9464
  • Type

    jour

  • DOI
    10.1109/TMAG.2012.2198620
  • Filename
    6332571