• DocumentCode
    1336456
  • Title

    Fast Exact/Quasi-Exact FBP Algorithms for Triple-Source Helical Cone-Beam CT

  • Author

    Lu, Yang ; Katsevich, Alexander ; Zhao, Jun ; Yu, Hengyong ; Wang, Ge

  • Author_Institution
    Dept. of Biomed. Eng., Shanghai Jiao Tong Univ., Shanghai, China
  • Volume
    29
  • Issue
    3
  • fYear
    2010
  • fDate
    3/1/2010 12:00:00 AM
  • Firstpage
    756
  • Lastpage
    770
  • Abstract
    Cardiac computed tomography (CT) has been improved over past years, but it still needs improvement for higher temporal resolution in the cases of high or irregular cardiac rates. Given successful applications of dual-source cardiac CT scanners, triple-source cone-beam CT seems a promising mode for cardiac CT. In this paper, we propose two filtered-backprojection algorithms for triple-source helical cone-beam CT. The first algorithm utilizes two families of filtering lines. These lines are parallel to the tangent of the scanning trajectory and the so-called L lines. The second algorithm utilizes two families of filtering lines tangent to the boundaries of the Zhao window and L lines, respectively, but it eliminates the filtering paths along the tangent of the scanning trajectory, thus reducing the required detector size greatly. The first algorithm is theoretically exact for r < 0.265 R and quasi-exact for 0.265 R ?? r < 0.495 R, and the second algorithm is quasi-exact for r < 0.495 R, where r and R denote the object radius and the trajectory radius, respectively. Both algorithms are computationally efficient. Numerical results are presented to verify and showcase the proposed algorithms.
  • Keywords
    computerised tomography; filtering theory; medical image processing; L lines; cardiac computed tomography; fast exact FBP algorithms; filtered backprojection; quasiexact FBP algorithms; scanning trajectory; triple-source helical cone-beam CT; Biomedical engineering; Computed tomography; Data acquisition; Detectors; Filtering algorithms; Heart; Mathematics; Research and development; Sensor arrays; Spatial resolution; Cardiac CT; computed tomography (CT); cone-beam CT (CBCT); filtered backprojection (FBP); triple-source; Algorithms; Computer Simulation; Cone-Beam Computed Tomography; Image Processing, Computer-Assisted; Models, Theoretical; Phantoms, Imaging;
  • fLanguage
    English
  • Journal_Title
    Medical Imaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0278-0062
  • Type

    jour

  • DOI
    10.1109/TMI.2009.2035617
  • Filename
    5338022