  • Abstract
    The direct measurement of losses in power electronic systems is possible through the use of a calorimeter. An improved and fully automated version of a double-jacketed closed-type calorimeter is described in this paper. The accuracy of the calorimeter has been confirmed by calibration tests and is better than 0.1 W in 25 W. The losses in mobile (cell phone) chargers and the ballasts of compact fluorescent lamps have been measured in this calorimeter and are compared to those obtained from conventional measurement methods.
  • Keywords
    calorimeters; calorimetry; fluorescent lamps; heat losses; lamp accessories; loss measurement; power electronics; ballasts; compact fluorescent lamps; double-jacketed closed-type calorimeter; losses measurement; mobile chargers; power electronic devices; precision calorimetry; Calorimeter; compact fluorescent lamp (CFL); component; loss measurement; mobile charger;