DocumentCode
1338840
Title
Precision Calorimetry for the Accurate Measurement of Losses in Power Electronic Devices
Author
Weier, Sven ; Shafi, Mohsin A. ; McMahon, Richard
Author_Institution
Eng. Dept., Univ. of Cambridge, Cambridge, UK
Volume
46
Issue
1
fYear
2010
Firstpage
278
Lastpage
284
Abstract
The direct measurement of losses in power electronic systems is possible through the use of a calorimeter. An improved and fully automated version of a double-jacketed closed-type calorimeter is described in this paper. The accuracy of the calorimeter has been confirmed by calibration tests and is better than 0.1 W in 25 W. The losses in mobile (cell phone) chargers and the ballasts of compact fluorescent lamps have been measured in this calorimeter and are compared to those obtained from conventional measurement methods.
Keywords
calorimeters; calorimetry; fluorescent lamps; heat losses; lamp accessories; loss measurement; power electronics; ballasts; compact fluorescent lamps; double-jacketed closed-type calorimeter; losses measurement; mobile chargers; power electronic devices; precision calorimetry; Calorimeter; compact fluorescent lamp (CFL); component; loss measurement; mobile charger;
fLanguage
English
Journal_Title
Industry Applications, IEEE Transactions on
Publisher
ieee
ISSN
0093-9994
Type
jour
DOI
10.1109/TIA.2009.2036667
Filename
5339204