• DocumentCode
    1339363
  • Title

    A Minimal Set of Electrodes for Motor Imagery BCI to Control an Assistive Device in Chronic Stroke Subjects: A Multi-Session Study

  • Author

    Tam, Wing-Kin ; Tong, Kai-yu ; Meng, Fei ; Gao, Shangkai

  • Author_Institution
    Dept. of Health Technol. & Inf., Hong Kong Polytech. Univ., Kowloon, China
  • Volume
    19
  • Issue
    6
  • fYear
    2011
  • Firstpage
    617
  • Lastpage
    627
  • Abstract
    The brain-computer interface (BCI) system has been developed to assist people with motor disability. To make the system more user-friendly, it is a challenge to reduce the electrode preparation time and have a good reliability. This study aims to find a minimal set of electrodes for an individual stroke subject for motor imagery to control an assistive device using functional electrical stimulation for 20 sessions with accuracy higher than 90%. The characteristics of this minimal electrode set were evaluated with two popular algorithms: Fisher´s criterion and support-vector machine recursive feature elimination (SVM-RFE). The number of calibration sessions for channel selection required for robust control of these 20 sessions was also investigated. Five chronic stroke patients were recruited for the study. Our results suggested that the number of calibration sessions for channel selection did not have a significant effect on the classification accuracy. A performance index devised in this study showed that one training day with 12 electrodes using the SVM-RFE method achieved the best balance between the number of electrodes and accuracy in the 20-session data. Generally, 8-36 channels were required to maintain accuracy higher than 90% in 20 BCI training sessions for chronic stroke patients.
  • Keywords
    bioelectric phenomena; biomedical electrodes; brain-computer interfaces; calibration; image sensors; machine control; medical control systems; neurophysiology; performance index; robust control; support vector machines; Fisher criterion; SVM-RFE method; assistive device control; brain-computer interface system; calibration session; channel selection; chronic stroke patient; chronic stroke subject; classification accuracy; electrode preparation time; functional electrical stimulation; minimal electrode set; motor disability; motor imagery BCI; performance index; robust control; support vector machine recursive feature elimination; Band pass filters; Brain modeling; Electrodes; Electroencephalography; Patient rehabilitation; Support vector machines; Brain–computer interface (BCI); electrical stimulation; patient rehabilitation; support vector machine (SVM); Adult; Aged; Algorithms; Brain; Calibration; Cerebral Cortex; Chronic Disease; Data Interpretation, Statistical; Electric Stimulation; Electrodes; Electroencephalography; Female; Functional Laterality; Humans; Imagination; Male; Middle Aged; Movement; Online Systems; Psychomotor Performance; Self-Help Devices; Stroke; Support Vector Machines; User-Computer Interface;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2011.2168542
  • Filename
    6034528