DocumentCode
1345710
Title
A detailed study of losses in the reduced voltage resonant link inverter topology
Author
Deshpande, Vijay V. ; Doradla, Seshagiri Rao
Author_Institution
Dept. of Electr. Eng., Indian Inst. of Technol., Kanpur, India
Volume
13
Issue
2
fYear
1998
fDate
3/1/1998 12:00:00 AM
Firstpage
337
Lastpage
344
Abstract
A new reduced voltage resonant link (RVRL) topology was reported earlier. A detailed study of the effect of various parameters such as the characteristic impedance, Q factors, input DC voltage and the resonant frequency on the link losses is presented. The voltage and current stresses on various link components are also given. The losses are determined and then compared with those of the actively clamped resonant DC link. The RVRL topology reduces the link losses by 25% under certain operating conditions. The new topology being truly resonant offers less EMI and requires less number of power devices. It is particularly suitable at high resonant frequencies with ease of control
Keywords
DC-AC power convertors; invertors; losses; resonant power convertors; switching circuits; Q factors; characteristic impedance; current stresses; input DC voltage; link losses study; operating conditions; reduced voltage resonant link inverter topology; resonant frequencies; resonant frequency; voltage stresses; Circuit topology; Clamps; Impedance; Inverters; RLC circuits; Resonance; Resonant frequency; Stress; Switches; Voltage;
fLanguage
English
Journal_Title
Power Electronics, IEEE Transactions on
Publisher
ieee
ISSN
0885-8993
Type
jour
DOI
10.1109/63.662852
Filename
662852
Link To Document