DocumentCode
1346895
Title
Negative-sequence voltage detection on aircraft A-C electric systems
Author
Jessee, R. D. ; Boggess, P. F.
Author_Institution
Westinghouse Electric Corporation, Lima, Ohio
Volume
75
Issue
3
fYear
1956
fDate
7/1/1956 12:00:00 AM
Firstpage
171
Lastpage
175
Abstract
SHORT circuits or grounds in aircraft electric power systems or in other parts of the electric system cause unbalanced voltages. These voltages may be detected by several means. One method indicated by a study of symmetrical components is the negative-sequence voltage.1 It can be shown that line-to-line and line-to-ground fault detection can be provided by sensing the negative-sequence voltage.
Keywords
Aircraft; Circuit faults; Equations; Harmonic analysis; Power harmonic filters; Relays; Sensors;