DocumentCode
1354658
Title
Sparkover as influenced by surface conditions in D-C Corona
Author
Penney, Gaylord W. ; Craig, Samuel E.
Author_Institution
Carnegie Institute of Technology, Pittsburgh, Pa.
Volume
79
Issue
2
fYear
1960
fDate
5/1/1960 12:00:00 AM
Firstpage
112
Lastpage
118
Abstract
Sparkover between clean electrodes has been investigated extensively but it is found that sparkover between contaminated electrodes exhibits very different results. With corona from a clean metal point to a plane, sparkover occurs at a considerably lower voltage if the point is positive.1 Because of this, it is frequently assumed that positive corona will always result in the lowest sparkover voltage. A few experiments with contaminated electrodes show that sparkover is a complicated phenomenon and that negative corona does not always result in a higher sparkover voltage.
Keywords
Conductivity; Corona; Electrodes; Magnetic hysteresis; Magnetic tunneling; Materials; Wires;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher
ieee
ISSN
0097-2452
Type
jour
DOI
10.1109/TCE.1960.6368553
Filename
6368553
Link To Document